2.6 Connecting Doorphones and Door Openers
2.6.1 Connecting Doorphones and Door Openers
Up to 4 doorphones (KX-T30865) and 4 door openers (user-supplied) can be installed. |
Maximum Cabling Distance
Door opener current limit: 30 V DC/125 V AC, 3 A maximum
|
Installing the Doorphone (KX-T30865)
1. |
Loosen and remove the screw at the bottom of the case to separate the doorphone into 2 halves. |
|
|
2. |
Pass the wires through the hole in the base cover, and attach the base cover to a wall using 2 screws. |
|
|
|
Note
|
Two kinds of screws are included with the KX-T30865. Please choose the appropriate screws for your wall type. |
|
|
|
|
when a doorphone plate has been fixed to the wall |
|
|
|
when you wish to install the doorphone directly to the wall |
|
|
3. |
Connect the wires to the screws located in the front cover. |
|
|
4. |
Re-attach the 2 halves and re-insert and tighten the screw. |
Connecting Doorphones (KX-T30865)
1. |
Connect the Doorphone Card to the terminal boxes using 4-conductor wiring and modular connectors. |
2. |
Connect the wires of doorphones 1 and 3 to the red and green screws on the appropriate terminal box. |
3. |
Connect the wires of doorphones 2 and 4 to the yellow and black screws on the appropriate terminal box. |
|
|
Connecting Door Openers
1. |
Use a flathead screwdriver to press and hold open the button below the terminal, and insert the wire coming from the door opener into the terminal. |
|
|
|
|
2. |
Wrap the strap around all of the cords. (→ 2.2.4 Securing Cords) |
Notes
|
• |
We recommend using UL1015 wire or an equivalent for wiring. |
|
• |
The wire should be between 0.45 mm and 1.1 mm in diameter excluding the coating. |